Scaffolding
Scaffold Frames in Mason Style, Light Duty and Walk-Thru Designs, With Matching Braces, Pins and More
Tube sizes for mason and light duty frames, heights from 24 to 76 inches, 24, 48 and 60 inch widths, the cross brace each size takes, coupling pins, and the OSHA stacking and tie-in rules for frame towers.
Choosing scaffold frames starts with grade and size, since the frame decides how much a scaffold tower carries, how high each lift climbs and which braces, planks and rails fit it. Nation Wide Ladder lists the Standard Vanguard® style mason models and lighter duty models contractors order most, and our team matches each one to its cross braces and coupling pins, covering the mason style grade, the light duty grade, the walk-thru frame and the short sizes used to fine-tune a scaffold's height.
- Over 50 years serving contractors
- MA, NH, CT, ME, VT & RI
- Weekly Maine deliveries
Mason Style and Light Duty Scaffold Frames Compared by Tube and Wall
Most scaffold frames we list are mason style, sold under the Standard Vanguard® style name and built from steel tube with a 1.69 inch outside diameter, a 1-1/2 inch inside diameter and a .095 inch wall, finished in blue powder coat. That heavier tube is why masons, siding crews and general contractors choose the mason grade for an exterior scaffold carrying block, mortar or a crew with its material. The mason line runs from 60 inch wide models in five heights to narrower 24 inch wide models for tight spaces.
Light duty scaffold frames use a 1.25 inch outside diameter tube with a 1.078 inch inside diameter and a .086 inch wall, also in blue powder coat, and come 48 inches wide in 48 and 72 inch heights. They are easier to carry and suit a scaffold where the load is people and hand tools. Each grade takes its own coupling pins, casters and outriggers, so the grade you pick also sets the accessory list. OSHA allows components from different manufacturers in one scaffold only when they fit together without force and the user maintains its structural integrity, which is one more reason to buy each frame with its braces and pins as a set.
Tell us what the deck will carry, and our team will help you settle the scaffold grade first, then build the brace and pin list around it.
Scaffold Frames by Height and Width, With the Walk-Thru Model and Matching Cross Braces
Height is where scaffold frames vary most. The 60 inch wide mason line comes as the NWF5x2 at 24 inches tall, the NWF5x3 at 36, the NWF5x4 at 48, the NWF5x5 at 60 and the NWF5x64 at 76 inches, the tallest in the line. A shorter scaffold frame goes on top of or under a full one to land the deck where the work is. The 24 inch wide mason models come in 36 and 72 inch heights, and the NWFLD4x6 light duty frame stands 72 inches tall beside the 48 inch NWFLD4x4.
The NWFWT5x64 walk-thru frame shares the 60 by 76 inch size with an opening through the frame, so workers can pass between bays on the deck. Each size takes a specific brace. Our NWB cross braces are galvanized steel tubing that drop-lock onto the frame studs, and the listing pairs the 76 inch frames, walk-thru included, with the 7 by 4 foot brace, the 60 inch size with the 7 by 4 as well, the 48 inch size with the 7 by 3, the 36 inch size with the 7 by 2 and the 24 inch size with the 7 by 1. Stud spacing runs from 12 to 48 inches across these scaffold frames, which is what sets those pairings.
Send us the working heights and tower count, and we quote each scaffold frame with its matched brace, by phone at 603-434-6911 in NH or 508-754-3030 in MA.
Stacking, Pinning and Tying Scaffold Frames Into a Code-Compliant Tower
OSHA’s rule for fabricated frame scaffolds, 29 CFR 1926.452(c), sets out how scaffold frames go together. Each end frame is joined to the next vertically by coupling or stacking pins, braced by cross, horizontal or diagonal braces that square and align the uprights, and locked with pins wherever uplift could lift one off another. When a crew moves platforms up a level, the existing platform stays in place until the new end frames are set and braced, and any frame scaffold over 125 feet above its base plates has to be designed by a registered professional engineer.
Our NWCP coupling pins measure 9 inches long by 1 3/8 inch outside diameter with a 1 inch collar at the midpoint for the mason grade, and the NWLDCP light duty pin is 9 inches by 15/16 inch, each bolted or pinned in place with a locking pin. Height against base matters too. Under 1926.451(c)(1), a supported scaffold taller than four times its base width has to be guyed, tied or braced, starting at the closest horizontal member to that 4 to 1 height and repeating every 20 feet for a scaffold 3 feet wide or less, or every 26 feet for wider ones. Crossbraces may never be used to climb a scaffold tower.
Having served contractors for over 50 years, we can help you count the pins, ties and braces a scaffold tower needs before anything leaves our yard.
Scaffold Frames as the Base for Planks, Rails and Access
A scaffold tower becomes a work platform once planks, guardrails and a way up are added, and each of those parts is sized to the frame. The 7 foot hook-on decks we list match the 7 foot cross braces, guardrail posts come in light duty and mason versions, and the stairway and access ladder we list are built for a 6 foot 4 inch frame. Planning scaffold frames together with their scaffold planks keeps every bay consistent.
For racks, ladders and access gear from the other makers in our range, browse the truck and ladder equipment brands hub.
Ordering Scaffold Frames for Delivery to the Site
Nation Wide Ladder quotes scaffold frames as complete towers, with braces, pins, planks and rails counted to your heights, and our own trucks deliver them door to door across New Hampshire, Massachusetts, Connecticut, Rhode Island, Vermont and Maine. Our scaffolding overview sets frames beside pump jack and interior systems.
Scaffold Frames FAQs
What separates mason style and light duty scaffold frames?
Tube size. The mason grade uses 1.69 inch outside diameter steel tube with a .095 inch wall, while the light duty grade uses 1.25 inch tube with a .086 inch wall, and each takes its own pins and casters.
Which cross brace fits 76 inch scaffold frames?
The NWB 7 by 4 foot brace, which the listing also pairs with the walk-thru frame and the 60 inch tall frame.
Which scaffold frames fit narrow spaces?
The 24 inch wide mason style models, which come in 36 and 72 inch heights, against 48 and 60 inch widths for the rest of the scaffold range we list.
When do scaffold frames need to be tied to the building?
Once a supported scaffold is taller than four times its base width, OSHA 1926.451(c)(1) requires guys, ties or braces, repeated every 20 or 26 feet depending on width.
How are stacked scaffold frames held together?
With coupling or stacking pins, locked with a pin wherever uplift could separate one frame from the next, as OSHA 1926.452(c) requires.
Need help choosing the right ladder or truck equipment?
Talk to the team or send us your list and we will put a quote together.