Werner Fall Protection Anchors

Werner Post Anchor, a Permanent Galvanized Steel Roof Tie-Off Point on a 16 Inch Base Plate, with I-Beam Backer and More

The A525400 permanent roof anchorage compared on base plate, mounting surfaces, loading direction, strength, standards and how it fits planned, repeat-use roof access.

The Werner post anchor gives a roof a permanent tie-off point that maintenance crews and later trades can use again and again, instead of improvising anchorage on each visit. Nation Wide Ladder supplies the Werner A525400, a galvanized steel post on a 16 by 16 inch base plate that fastens to wood or concrete, or to an I-beam with the A525405 backer plate, rated at a 5,000 pound minimum breaking strength.

NH603-434-6911MA508-754-3030

  • Over 50 years serving contractors
  • MA, NH, CT, ME, VT & RI
  • Weekly Maine deliveries

Who Needs a Permanent Werner Post Anchor on the Roof

Werner lists the A525400 as a permanent anchorage for roof work, which suits buildings where people go up regularly, for rooftop equipment service, inspections, drain clearing or repeat trade visits. Installing a Werner post anchor once gives each of those visits a known tie-off point that does not have to be set up again.

Temporary roof anchorage has its place on a single job, but a building with regular roof traffic is better served by anchorage that stays put and can be inspected and logged like any other piece of fall protection. Werner uses galvanized steel for the whole assembly to resist corrosion, since a permanent Werner anchor stays outdoors through every season.

A permanent Werner anchor also changes how a crew plans the day. With the Werner tie-off point already in place, the first worker up connects to the post rather than spending the opening minutes of the job setting temporary hardware near the edge.

For jobs where temporary hardware fits better, our Werner fall protection anchors range also covers disposable roof anchorage, beam sliders and D-bolt hardware.

We help you decide where a permanent post makes sense and which Werner hardware suits the roof structure, before anything is fastened down.

Werner A525400 – Post Anchor

Werner Post Anchor Specifications, from Base Plate to Breaking Strength

The A525400 is built from corrosion-resistant galvanized steel. Its base plate measures 16 by 16 inches and is 3/8 inch thick, and Werner lists the assembled post at roughly 15 inches tall and about 38 pounds, so it is a two-handed carry onto a roof.

The Werner post can be loaded from any direction through 360 degrees, so a worker tied to it is not limited to one side, and Werner rates it at a minimum breaking strength of 5,000 pounds. That figure lines up with OSHA 1926.502, which calls for personal fall arrest anchorage that supports 5,000 pounds per attached worker unless a qualified person designs it as part of a system with a safety factor of at least two.

Werner lists the post as meeting ANSI Z359.18-2017 Type A, the standard for anchorage connectors, along with OSHA 1910.140 for general industry and 1926.502 for construction. See the Werner A525400 post anchor listing for the full product details. Werner backs the post with a technical data sheet and an instruction manual, which a qualified person should review before the post is specified for a roof.

Our Windham NH and Worcester MA showrooms offer free consultations where we can go over the base plate and fastening options for your roof.

Mounting, Inspecting and Planning Around a Werner Post

The post base plate is drilled for fastening to wood or concrete, and an I-beam mount needs the separate A525405 backer plate. Werner supplies an instruction manual for the post anchor, and the fasteners, substrate and installation steps should follow it exactly, with a qualified person confirming that the structure under the plate can carry the load.

Werner guidance on inspection applies here as well, with a check before each use and an inspection at least once a year by a competent person other than the user. Under OSHA, parts of a fall arrest system that take an impact load come out of service until a competent person confirms they are undamaged, so a post that has held a fall should be checked before anyone ties off to it again.

Plan the route to the post too, since crews still need a safe way onto the roof and across to the post before they can clip in. Werner leaves the post outside diameter and the number of users off its product listing, so confirm those details in the instruction manual before you plan the layout.

With over 50 years of serving homeowners and contractors, we plan the post location and the roof access route together with you.

Werner Post Anchor Placement and the Ladder Up to It

A permanent post on the roof is only half of safe roof access. The ladder or fixed route that gets workers there, the harness and lifeline they connect with, and the truck racks that carry ladders to the building often come from several manufacturers, and choosing them together keeps the route and the tie-off point in step.

To see the other makers we carry for that access gear, go to our ladder and truck equipment brands hub.

Quotes on the Werner Post Anchor for Your Building

A galvanized post on a 16 inch plate, 360 degree loading and a 5,000 pound minimum breaking strength give a roof a permanent tie-off point for repeat visits. Tell us the roof structure and how often crews go up, call 603-434-6911 in NH or 508-754-3030 in MA, and we will quote the Werner post anchor with any backer plate it needs. You can also browse our Werner store or return to the Werner brand page.

Werner Post Anchor FAQs

What size is the Werner post anchor base plate?

16 by 16 inches and 3/8 inch thick, in galvanized steel.

Can the Werner post anchor mount to an I-beam?

Yes, with the A525405 backer plate, which is sold separately. The base plate is also drilled for wood and concrete.

How strong is the Werner A525400 post?

Werner rates it at a minimum breaking strength of 5,000 pounds, loadable from any direction through 360 degrees.

Is the post anchor permanent or temporary?

Permanent. Werner designs the A525400 to stay on the roof as a repeat-use tie-off point.

What standards does the Werner post anchor meet?

Werner lists ANSI Z359.18-2017 Type A for anchorage connectors and OSHA 1910.140 and 1926.502.

Need help choosing the right Werner equipment?

Talk to the team or send us your list and we will put a quote together.

TOP
Nation Wide Ladder

Nation Wide Ladder